Relay search

Twitter
Delcon: 
I have 10 new followers from Spain, and more last week. See https://t.co/bTyoqR515o https://t.co/aV9U9Ae5or
Delcon: 
I have 11 new followers from UK., and more last week. See https://t.co/bTyoqR515o https://t.co/FknMK6SBYu

GLO 5CR

DC-output relay for resistive and slightly inductive loads.

 

 

Datasheet
Qualifications checkbox_on CE checkbox_on RoHS checkbox_on EAC
Delcon
MTTF (Mean Time To Failure): 10 years
PrimaryGLO 5CR
Input voltagenominalVDC5
Input currenttypicalmA12
maximummA15
Input voltage rangeminimumVDC3
maximumVDC7
Input impedancetypical0,42
Switch-on voltagetypicalVDC2,7
maximumVDC3
Switch-off voltagetypicalVDC2,5
minimumVDC2
SecondaryGLO 5CR
Load voltageminimumVDC0
nominalVDC60
maximumVDC66
Load currentmaximumA3
Voltage drop at maximum loadtypicalVDC0,5
Switch-on delaytypicalms0,3
maximumms0,5
Switch-off delaytypicalms0,3
maximumms0,5
Load inductance at 60 V 3 A, L/Rmaximumms0,5
Load inductance at 24 V 2 A, L/Rmaximumms5
Leakage current (off-state)maximummA1