Relay search

Twitter
Delcon: 
I have 10 new followers from Spain, and more last week. See https://t.co/bTyoqR515o https://t.co/aV9U9Ae5or
Delcon: 
I have 11 new followers from UK., and more last week. See https://t.co/bTyoqR515o https://t.co/FknMK6SBYu

SLI 230CRP

Works with leakage current from 2-wire proximity switches.

Application e.g. limit switches and long cables.

Main benefits comparing to electromechanical relays and opto coupled relays:

- No limited lifetime, 6 year warranty
- Relatively high tolerance against noises
- Guaranteed switching on and off -levels
- 100 % clear status indication
- Relatively high transient protection
- Extreme reliability
- No minimum load requirement

 

 

 

 

 

Datasheet 3D files
Qualifications checkbox_on CE checkbox_on RoHS checkbox_on cULus Listed Ind. Cont. Eq. checkbox_on EAC
Delcon
MTTF (Mean Time To Failure): 12,9 years
PrimarySLI 230CRP
Input voltagenominalVAC220...240
Input current at nominal voltagetypicalmA6,5
maximummA7,5
Input voltage rangeminimumVAC190
maximumVAC265
Input impedancetypicalkΩ35
Switch-on voltagetypicalVAC170
maximumVAC190
Switch-off voltagetypicalVAC140
minimumVAC120
Switch-off currenttypicalmA3,5
Crosstalk capacitance acceptancetypicalnF80
SecondarySLI 230CRP
Load voltageminimumVDC0
maximumVDC60
Load currentmaximummA50
Voltage drop at maximum loadtypicalVDC0,2
maximumVDC0,4
Switch-on delaytypicalms40
Switch-off delaytypicalms40
Leakage current (off-state)maximumµA1