SLO 24TRA

For 1-phase motor in on/off and reverse use.
Application e.g. all type of AC-loads.

Main benefits comparing to electromechanical relays and opto coupled relays:

- No limited lifetime even with difficult loads, 10 year warranty
- Handles all kind of AC-loads, no need for extra protection elements
- High tolerance against noises
- Guaranteed switching on- and off-levels
- 100 % clear status indication
- Relatively high transient protection
- Extreme reliability
- No need for over dimension of the relay, all values are effective values
- No minimum load requirement

Datasheet 3D files
Qualifications checkbox_on CE checkbox_on RoHS checkbox_on EAC
Delcon
MTTF (Mean Time To Failure): 422,4 years
PrimarySLO 24TRA
Input voltagenominalVDC24
Input currenttypicalmA15
maximummA17
Input voltage rangeminimumVDC18
maximumVDC32
Input impedancetypical1,4
Switch-on voltagetypicalVDC16
maximumVDC18
Switch-off voltagetypicalVDC14
minimumVDC12
SecondarySLO 24TRA
Load voltageminimumVAC0
nominal motor load/static loadVAC240/415
maximum motor load/static loadVAC265/460
Load currentmaximumA2,5
Load current 20 msmaximumA65
Voltage drop at maximum loadtypicalVAC1
Switch-on delaytypicalms0,5
maximumms1
Switch-off delaytypicalms-
maximumms11
Load inductance at 240 VAC 2,5 A/static loadrangecos Φ0...1
Leakage current (off-state)typicalµA50
dv/dt, off-statetypicalV/µs4000