EXO5TH
Application e.g. all type of AC-loads.
Main benefits comparing to electromechanical relays and opto coupled relays:
- No limited lifetime even with difficult loads, 10 year warranty
- Handles all kind of AC-loads, no need for extra protection elements
- High tolerance against noises
- Guaranteed switching on- and off-levels
- 100 % clear status indication
- Relatively high transient protection
- Extreme reliability
- No need for over dimension of the relay, all values are effective values
- No minimum load requirement
Datasheet
3D files

This relay has
365,3 years
MTTF (Mean Time To Failure)Primary
Input voltage | nominal | nominal | 5 |
Input current | typical | typical | 12 |
Input current | maximum | maximum | 15 |
Switch-on voltage | typical | typical | 2,7 |
Switch-on voltage | maximum | maximum | 3 |
Switch-off voltage | typical | typical | 2,5 |
Switch-off voltage | minimum | minimum | 2,0 |
Secondary
Load voltage | minimum | minimum | 0 |
Load voltage | nominal | nominal | 240 |
Load current | maximum | maximum | 3 |
Load current 20 ms | maximum | maximum | 90 |
Voltage drop at maximum load | typical | typical | 1 |
Switch-on delay | typical | typical | 0,5 |
Switch-on delay | maximum | maximum | 1 |
Switch-off delay | typical | typical | - |
Switch-off delay | maximum | maximum | 11 |
Load inductance at 240 VAC 3 A | range | range | 0...1 |
Leakage current (off-state) | typical | typical | 1,5 |
dv/dt, off-state | typical | typical | 200 |