GLI120CRP
AC-input relay
- for 2-wire proximity switches
- Compatible with 'G4' -pinning relays from other suppliers like OPTO22, Crydom, Grayhill etc.
Datasheet

This relay has
19,4 years
MTTF (Mean Time To Failure)Primary
Input voltage | nominal | nominal | 110...120 |
Input current at nominal voltage | typical | typical | 7 |
Input current at nominal voltage | maximum | maximum | 8 |
Input voltage range | minimum | minimum | 95 |
Input voltage range | maximum | maximum | 140 |
Input impedance | typical | typical | 17 |
Switch-on voltage | typical | typical | 80 |
Switch-on voltage | maximum | maximum | 95 |
Switch-off voltage | typical | typical | 60 |
Switch-off voltage | minimum | minimum | 50 |
Switch-off current | typical | typical | 3,5 |
Crosstalk capacitance acceptance | typical | typical | 80 |
Secondary
Load voltage | minimum | minimum | 0 |
Load voltage | maximum | maximum | 60 |
Load current | maximum | maximum | 50 |
Voltage drop at maximum load | typical | typical | 0,2 |
Voltage drop at maximum load | maximum | maximum | 0,4 |
Switch-on delay | typical | typical | 20 |
Switch-off delay | typical | typical | 40 |
Leakage current (off-state) | maximum | maximum | 1 |