Skip to main content
Home
  • About us
  • Relays
  • References
  • Distributors
  • Quality
  • Support
  • Contact

Product category

  • Relays for automation
    • DC control / DC load
    • DC control / AC load
    • AC control / DC load
    • AC control / AC load
    • Electromechanical relays
  • Relays for G4-pinning
    • DC control / DC load
    • DC control / AC load
    • AC control / DC load
  • Relays for Ex-environment
    • DC control / DC load
    • DC control / AC load
    • AC control / DC load
    • AC control / AC load
  • Mounting bases for DIN-rail and PCB
    • Bases for 1 relay
    • Bases for 8 relays
    • Bases for 16 relays
    • PCB Sockets
  • Accessories
    • PLC-Adapters
    • Connecting cables for PLC
    • Motor control
    • Jumpers for cross connecting relays
    • Logic converters
  • Help Center
    • Documents, brochures and problem solving information

DC control / DC load

Relays with DC-input ("coil") voltage and DC-load voltage
 

  • SLI -relays for mA-size loads e.g. PLC-input, filters against noise from cable capacitance
    • Used between sensors/switches & PLC for isolation (4600VAC rms), voltage adapting and as a noise filter to prevent malfunction
  • SLO -relays for ampere-size loads e.g. solenoid valves, pumps, fans, contactors, heaters, lighting and motors

 

Delcon relay benefits comparing to electromechanical relays and opto's:

  • Works from zero loads upwards --> no minimum load requirement
  • Extremely low leakage current
  • Built in suppression circuits on a signal sides to ensure that they work correctly in industrial areas with high interference levels originated by cable capacitance
  • Built-in protection (varistor, diode, RC-circuit etc.) for the switching component to extend reliability and life time even more
  • 100 % clear status indication, LED is synchronized with the output
  • Breakdown voltage Input/Output 4600VAC rms
  • 10 year warranty
Delcon

Relay list

Product name Application Control voltage Load voltage Max. current Sort descending
SLO24COA Change-over function (SPDT-CO) 24 VDC 0...250 VDC 0,8 A
SLO5CRA Inductive loads, MOSFET output for Solenoid Valves 5 VDC 0...250 VDC 1,8 A
SLO24CRAI Normally closed function, Inductive loads 24 VDC 0...250 VDC 1,8 A
SLO24CRXSN Resistive loads, DIN-rail socket included 24 VDC 0...24 VDC 10 A
SLO12CRXSN Resistive loads, DIN-rail socket included 12 VDC 0...24 VDC 10 A
SLO5CRXSN Resistive loads, DIN-rail socket included 5 VDC 0...24 VDC 10 A
SLO48CRXSN Resistive loads, DIN-rail socket included 48 VDC 0...24 VDC 10 A
SLI125CRI Normally closed operation 125 VDC 0...60 VDC 100 mA
SLI48CRI Normally closed operation 48 VDC 0...60 VDC 100 mA
SLI12CRI Normally closed operation 12 VDC 0...60 VDC 100 mA
SLI24CRI Normally closed operation 24 VDC 0...60 VDC 100 mA
SLI250CRI Normally closed operation 220...250 VDC 0...60 VDC 100 mA
SLO5CR Resistive and slightly inductive loads 5 VDC 0...60 VDC 3 A
SLO12CR Resistive loads 12 VDC 0...60 VDC 3 A
SLO24CL Low input current 24 VDC 0...60 VDC 3 A
SLO24CR Resistive and slightly inductive loads 24 VDC 0...60 VDC 3 A
SLO37CH Resistive and inductive loads, wide input voltage range for battery driven applications 24...37 VDC 0...110 VDC 4 A
SLO24CRA5 Inductive loads, MOSFET output for Solenoid Valves 24 VDC 0...350 VDC 5 A
SLO12CRA5 Resistive loads 12 VDC 0...60 VDC 5 A
SLO120CRA5 Inductive loads, MOSFET output for Solenoid Valves 120 VDC 0...250 VDC 5 A
SLO220CRA5 Inductive loads, MOSFET output for Solenoid Valves 220 VDC 0...250 VDC 5 A
SLO48CRA5 Inductive loads, MOSFET output for Solenoid Valves 48 VDC 0...250 VDC 5 A
SLI125CR Between sensors/switches & PLC, cable noise filters 125 VDC 0...60 VDC 50 mA
SLI48CR Between sensors/switches & PLC, cable noise filters 48 VDC 0...60 VDC 50 mA
SLI12CR Between sensors/switches & PLC, cable noise filters 12 VDC 0...60 VDC 50 mA
SLI24CR Between sensors/switches & PLC, cable noise filters 24 VDC 0...60 VDC 50 mA
SLI24CRF Fast connection 24 VDC 0...60 VDC 50 mA
SLI24CRL Increased input current 24 VDC 0...60 VDC 50 mA
SLI250CH Input protected from transients 220...250 VDC 0...60 VDC 50 mA
SLI250CR Between sensors/switches & PLC, cable noise filters 220...250 VDC 0...60 VDC 50 mA
SLI125CH Input protected from transients 125 VDC 0...60 VDC 50 mA
SLO24CRAI7 Normally closed function, Resistive loads 24 VDC 0...60 VDC 7 A
SLO5CRX Resistive and slightly inductive loads 5 VDC 0...24 VDC 8,3 A
SLO12CRX Resistive and slightly inductive loads 12 VDC 0...24 VDC 8,3 A
SLO24CRX Resistive and slightly inductive loads 24 VDC 0...24 VDC 8,3 A
SLO48CRX Resistive and slightly inductive loads 48 VDC 0...24 VDC 8,3 A