Nominal load voltage | 300 V DC |
Nominal input voltage | 5 V DC |
Rated load current | 5 A |
MTTF (MIL-HDBK-217F) | 137 years |
Input voltage max. | 7 V DC |
Switch-on voltage | 2,7 V DC |
Switch-off voltage | 2,5 V DC |
Power consumption | 60 mW |
Input impedance | 0,42 kΩ |
Load current range | 0 - 5 A |
Load voltage range | 0 - 380 V DC, no minimum load required |
Inrush current | 20 A, 10 ms |
Max. Inductive load, L/R | 5 ms (380 V, 5 A) |
Max. Inductive load, L/R | 50 ms (24 V, 5 A) |
Leakage current | 1 mA |
Voltage drop | 0,6 V |
Switch-on time | 0,3 ms |
Switch-off time | 0,3 ms |
Insulation method | Pulse transformer (an unique feature for Delcon relay compared to opto) |
Test voltage input/output | 4600 V ACrms / 1 s |
Overvoltage category | III |
Pollution degree | 2 |
Air/creepage distance I/O | 8 mm |
Conductor size, screw terminal | 2,5 mm2 |
Conductor size, spring terminal | 0,75 - 2,5 mm2 |
Operating temperature | -40 °C to +70 °C |
Weight | 40 g |
Housing material flammability | UL 94 V-0 |
Package size | 10, 50 and 100 |