SLO24CRX

DC input, DC load — 8 A signal relay

Nominal input 24 V DC
Load voltage 24 V DC
Load current 8 A
Warranty 10 years
MTTF 34 years

41,66 €

Manufacturer's recommended price. Delivery terms: EXW Nummela, Finland.

10-year warranty ISO 9001:2015

Technical specifications

Main data
Nominal input voltage 24 V DC
Nominal load voltage 24 V DC
Rated load current 8 A
Contact type N/O, solid state
Coil type DC
Load circuit DC
EAN / GTIN 6410027190587
Application For resistive and inductive DC loads within datasheet limits
General data & attachments
Datasheet (PDF) Open
3D model files Open
Relay selection tool Open

Why choose SLO24CRX

Defined high-current DC performance

Use SLO24CRX when a nominal 24 VDC controller output must switch a higher-current DC load without mechanical contacts. Pulse-transformer isolation, no minimum load requirement and a replaceable SL-series package support dependable industrial control panels.

8 A published continuous rating

Use the full published rating within the datasheet’s stated ambient, cooling and installation conditions; no additional arbitrary reduction factor is needed.

0–32 VDC load range

No minimum load voltage or current is required within the published range.

80 A / 10 ms inrush

Short-duration capability for load-current peaks must still be checked against the real application.

Pulse-transformer isolation

4,600 VAC RMS input/output test voltage with 8 mm air and creepage distance.

Application guidance

Match the relay to the actual DC load

Suitable applications

  • High-current 24 VDC resistive loads
  • DC valves, solenoids and contactor coils within the published L/R limit
  • Applications requiring frequent, contactless switching
  • Panels needing a replaceable plug-in relay with local status indication

Check before selection

  • Verify that the real load remains within 0–32 VDC and 0–8 A.
  • For inductive loads, verify L/R against the published 2 ms limit at 24 V / 5 A and use suitable suppression.
  • Check inrush against the 80 A / 10 ms limit and select a correctly rated fast fuse.
  • Follow the datasheet instructions for cooling, side-by-side mounting and horizontal DIN-rail installation.
Delcon design advantage: the control command crosses a pulse-transformer isolation barrier instead of an optocoupler. See how Delcon technology works →

Complete the assembly

Sockets, alternatives and PLC Fast Connect

For multi-channel installations, select the mounting base, relay, cable and PLC adapter as one verified system. Delcon can also design and manufacture a custom cable, adapter or complete connection solution for any PLC, DCS or remote-I/O system.

Frequently asked questions

SLO24CRX selection basics

Can SLO24CRX carry 8 A continuously?

Yes. The datasheet specifies a continuous load-current range of 0–8 A. Use that rating within the stated ambient, cooling and installation conditions; do not add an arbitrary extra reduction factor.

Can it switch inductive DC loads?

Yes, when the load remains within the published limit of L/R 2 ms at 24 V / 5 A. Use suitable suppression and verify the actual inrush and stored energy.

Does it require a minimum load?

No. The datasheet specifies 0–32 VDC and 0–8 A load ranges with no minimum load requirement.

Which socket or mounting base should be used?

Use MOS1GN for screw terminals or MOS1CCN for spring terminals. For multi-channel PLC Fast Connect assemblies, use a compatible MBS mounting base, cable and PLC adapter as one verified system.

✓ Source: corrected SLO24CRX datasheet · Technically reviewed by Delcon Oy · Review date: 7 October 2026

Confirm SLO24CRX against the actual DC load.

Send Delcon the control voltage, load current, inrush, inductance, switching frequency, protection and installation conditions.

Discuss your application →