SLI230CR

AC input, DC load — 50 mA signal relay

Nominal input 240 V AC
Load voltage 24 V DC
Load current 50 mA
Warranty 10 years
MTTF 17 years

30,92 €

Manufacturer's recommended price. Delivery terms: EXW Nummela, Finland.

10-year warranty ISO 9001:2015

Technical specifications

Main data
Nominal input voltage 240 V AC
Nominal load voltage 24 V DC
Rated load current 50 mA
Contact type N/O, solid state
Coil type AC
Load circuit DC
EAN / GTIN 6410027191102
Application Immune against noises
General data & attachments
Datasheet (PDF) Open
3D model files Open
Relay selection tool Open

Why choose SLI230CR

Built for a defined industrial duty

Use SLI230CR to bring a 240 VAC field signal safely to a 24 VDC PLC input or similar low-current control load. Its defined switching thresholds and signal-side hysteresis help prevent electrical interference from becoming an unintended switching command.

Defined 160 / 120 VAC thresholds

Separate turn-on and turn-off levels provide predictable switching behaviour.

Only 1 µA leakage

A clearly specified low off-state current on the PLC-input side.

No minimum load

The solid-state output works from 0 to 50 mA and 0 to 60 VDC.

Pulse-transformer isolation

4,600 VAC RMS / 1 s test voltage between field and controller sides.

Application guidance

Use it where its strengths matter

Suitable applications

  • 240 VAC field signals to PLC or DCS inputs
  • Low-current 24 VDC control inputs
  • Industrial panels requiring galvanic field/controller isolation
  • Applications needing defined switch-on and switch-off thresholds

Check before selection

  • Maximum load current is 50 mA; this relay is intended for PLC inputs and similar low-current loads.
  • If switching an inductive load, install a clamp diode across the load as required by the datasheet.
  • Verify the actual field voltage against the 160 VAC turn-on and 120 VAC turn-off thresholds.
  • Apply thermal derating and horizontal-mounting guidance for dense installations.
Delcon design advantage: the control command crosses a pulse-transformer isolation barrier. The model-specific solid-state output stage is then selected for the actual AC, DC or PLC-input duty. See how the technology works →

Complete the assembly

Verified sockets and bus bars

For multi-channel installations, Delcon PLC Fast Connect™ mounting bases, cables and PLC adapters are also described in the product datasheet.

Related products and guides

Continue your selection

Compare the closest Delcon alternatives and review the application guidance before final selection.

Frequently asked questions

SLI230CR selection basics

What does SLI230CR connect?

It accepts a nominal 240 VAC field signal and provides a solid-state DC output intended for PLC inputs and similar loads.

Why are separate switching thresholds useful?

The relay turns on at 160 VAC and turns off at 120 VAC. This hysteresis provides a defined state change instead of a single ambiguous switching point.

What is the off-state leakage current?

The specified output leakage current is 1 µA. Always confirm that value against the PLC input requirements.

Can it drive an inductive load?

It is intended for PLC inputs and similar loads. If an inductive load is used, the datasheet requires a clamp diode across the load.

✓ Source: SLI230CR datasheet · Technically reviewed by Delcon Oy · Review date: 5 October 2026

Confirm SLI230CR against your real field signal and PLC input.

Send Delcon the voltage, current, inrush or inductive data, switching frequency and ambient conditions.